Short description
I/O module 8 digital inputs/outputs 9 to 32 VDC for 1-wire connections
General information
B&R ID code 0xEBC2
Status indicators -
Diagnostics
Diagnostic outputs In the application using current measurement
Power consumption 0.91 W
Electrical isolation
Digital - Digital No
Certifications
UN ECE-R10 Yes
CE Yes
UKCA Yes
Multi-function outputs
Multifunction PWM outputs (MF-PWM)
Quantity 8
Functions 4 A nominal current / channel
PWM frequency 15 Hz to 1 kHz,
digital input/output, sink/source circuit - configurable per channel, configurable software input filter, configurable switch-on/switch-off ramp, integrated output protection
Digital inputs
Quantity 0 to 8, depends on the use of multifunction inputs/outputs
Input voltage 9 to 32 VDC
Input current at 24 VDC Typ. 2.7 mA
Input circuit Sink/Source, configurable
Input filter
Hardware 100 µs
Software Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments
Input resistance Typ. 9 kΩ
Switching threshold 45% supply voltage
Digital outputs
Quantity 0 to 8, depends on the use of multifunction inputs/outputs
PWM output
Quantity 0 to 8, depends on the use of multifunction inputs/outputs
Nominal voltage 12/24 VDC
Supply voltage (permissible range) 9 to 32 VDC
Nominal current 4 A
Summation current 16 A
PWM frequency 15 Hz to 1 kHz
Duty cycle 0 to 100% in 0.1% steps, resolution <50 μs
Output circuit Sink/Source
Output protection Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
Variant Current-sourcing/Current-sinking FET
Diagnostic status Output monitoring with 1 ms delay
Leakage current when the output is switched off Max. 50 µA
Residual voltage <0.1 V at 4 A nominal current
Peak short-circuit current 50 A (max. 0.2 ms)
Current measurement
Current measurement range ±10 A
Conversion time 40 μs
Resolution 12-bit (6 mA)
Output format
Data type INT 0x8001 to 0x7FFF
Current 1 LSB = 305 μA
Accuracy ±0.5% ±50 mA
Temperature drift ±0.02%/°C ±1 mA/°C
Common mode error ±3 mA/V
Operating conditions
Mounting orientation
Any Yes
Degree of protection per EN 60529 Up to IP69K
Ambient conditions
Temperature
Operation
Horizontal mounting orientation -40 to 85°C housing surface
Vertical mounting orientation -40 to 85°C housing surface
Storage -40 to 85°C
Transport -40 to 85°C
Relative humidity
Operation 5 to 100%, condensing
Storage 5 to 100%, condensing
Transport 5 to 100%, condensing
Mechanical properties
Dimensions
Width 47 mm
Length 95 mm
Número do material:
X90PO210.08-00
Descrição:
  • 9 to 32 VDC
  • 8 PWM outputs
  • 4 A per channel
  • Current measurement
  • Central cutoff
  • X2X Link

The PWM option board offers 8 additional analog outputs that can also be used as digital inputs/outputs. Communication to the mainboard is implemented using X2X Link. In addition, the PWM option board provides current measurement for each channel.

Atualizações de HW Automation Studio Version (Data) Download
V4.3 HW Upgrade (X90PO210.08-00) EXE / 1 MB
Certificados Version (Data) Download
EU Declaration Industrial sector X90 PDF / 163 KB
EU Declaration Mobile machinery X90 PDF / 146 KB
EU Declaration Railway X90 PDF / 224 KB
UK Declaration Industrial sector X90 PDF / 110 KB
UN ECE-R10 PDF / 382 KB
Documentação Version (Data) Download
Datasheet X90PO210.08-00 PDF / 358 KB
X90 mobile System User´s Manual PDF / 49 MB
E-CAD (Modelos Electro ou EPLAN) Version (Data) Download