Short description
I/O module 2 relays with 1 normally open contact each, 230 VAC / 6 A, 24 VDC / 6 A
General information
B&R ID code 0xD205
System requirements
Automation Studio 3.0.81.15 or later
Automation Runtime 3.00 or later
SafeDESIGNER 2.70 or later
Safety Release 1.2 or later
mapp Technology Package mapp Safety 5.7.0 or later
Status indicators I/O function per channel, operating state, module status
Diagnostics
Module run/error Yes, using LED status indicator and software
Outputs Yes, using LED status indicator and software
Blackout mode
Scope Module
Function Module functionality
Standalone mode No
Max. I/O cycle time 1 ms
Power consumption
Bus 0.26 W
Internal I/O 1.15 W
Additional power dissipation caused by actuators (resistive) [W] 1.44
Electrical isolation
Channel - Bus Yes
Channel - Channel Yes
Certifications
CE Yes
UKCA Yes
Functional safety cULus FSPC E361559
Energy and industrial systems
Certified for functional safety
ANSI UL 1998:2013
Functional safety IEC 61508:2010, SIL 3
EN 62061:2005/A2:2015, SIL 3
EN ISO 13849-1:2015, Cat. 4 / PL e
IEC 61511:2004, SIL 3
Functional safety EN 50156-1:2004
ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
UL cULus E115267
Industrial control equipment
HazLoc cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
KC Yes
Relays
EN 50155 Yes
EN 61810-3 Yes
Safety characteristics
EN ISO 13849-1:2015
MTTFD per channel 2500 years
Mission time Max. 20 years
IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013
PFH / PFHd per channel <1*10-10
PFH / PFHd
openSAFETY wired Negligible
openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour
PFD per channel <2*10-5
Proof test interval (PT) 20 years
Safe relay channels
EN ISO 13849-1:2015
Category Cat. 1 if the relay channel is used individually,
Cat. 4 if 2 relay channels are connected in series
PL PL c if the relay channel is used individually,
PL e if 2 relay channels are connected in series
B10d
DC1, 24 VDC 6 A / 780,000
AC1, 230 VAC 6 A / 780,000
AC15, 230 VAC 3 A / 1,960,000
DC13, 24 VDC 5 A / 780,000
IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013
SIL CL SIL 1 if the relay channel is used individually,
SIL 3 if 2 relay channels are connected in series
I/O power supply
Nominal voltage 24 VDC
Voltage range 24 VDC -15% / +20%
Integrated protection Reverse polarity protection
Relay outputs
Quantity 2
Variant Relay / Normally open contact, internal high-side and low-side control
Nominal output current 5 mA to 6 A
Diagnostic status Contact position determined by positively driven contacts
Max. switching frequency See section "Inrush current behavior for output channels".
Switching delay
0 → 1 <50 ms
1 → 0 <50 ms
Insulation voltage between channel and bus Safe disconnection of 300 VAC per EN 50178
Insulation voltage between channel and channel Tested at 1350 VAC
Contact resistance (without terminal block) 20 mΩ
Contact service life See "Contact service life".
Short-circuit/Overload protection External 6 A gL/gG fuse (melting fuse), LS automat C characteristic 1.6 A
Switching voltage range 5 to 24 VDC, 5 to 230 VAC
Coil voltage 24 VDC -15% / +20%
Short-circuit proof Yes, 1000 A (with specified short-circuit/overload protection)
Max. inrush current 30 A for 20 ms
Overvoltage category per EN 60664-1 II
Max. switching capacity
AC1 230 VAC / 6 A
AC15 230 VAC / 3 A
DC1 24 VDC / 6 A
DC13 24 VDC / 5 A / 0.1 Hz
UL 508 B300 / R300
Operating conditions
Mounting orientation
Horizontal Yes
Vertical Yes
Installation elevation above sea level 0 to 2000 m, no limitation
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation 0 to 60°C
Vertical mounting orientation 0 to 50°C
Derating See section "Derating".
Storage -40 to 85°C
Transport -40 to 85°C
Relative humidity
Operation 5 to 95%, non-condensing
Storage 5 to 95%, non-condensing
Transport 5 to 95%, non-condensing
Mechanical properties
Note Order 1x safety-keyed terminal block separately.
Order 1x safety-keyed bus module separately.
Pitch 25+0.2 mm
Número de material:
X20SO2530
Descripción:
  • 2 safe relay outputs
  • Output type "Relay"
  • Relay module for 230 VAC / 24 VDC
  • Switching current 6 A
  • Normally open contact
  • Single-channel isolated outputs

This module is equipped with 2 safe relay outputs.

The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3.

Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur.

This module is designed for X20 12-pin terminal blocks.

Accesorios obligatorios
Bus modules
X20BM33 X20 bus module, for X20 SafeIO modules, internal I/O power supply connected through
X20BM36 X20 bus module, for X20 SafeIO modules, with node number switch, internal I/O power supply connected through
Terminal blocks
X20TB72 X20 terminal block, 12-pin, safety-keyed, 240 VAC, red
Actualizaciones de hardware de Automation Studio Versión (fecha) Descargar
V3.0 HW Upgrade (X20SO2530) EXE / 980 KB
V4.0 HW Upgrade (X20SO2530) EXE / 2 MB
V4.6 HW Upgrade (X20SO2530) EXE / 2 MB
V6.0 HW Upgrade (X20SO2530) EXE / 2 MB
Certificados Versión (fecha) Descargar
244665 CSA HazLoc CoC X20, X67 PDF / 158 KB
E115267 UL CoC X20 PDF / 1 MB
EU Declaration FS PLC X20 PDF / 210 KB
FS Certificate SafeDESIGNER, SafeLOGIC, SafeIO PDF / 1 MB
FS Certificate mapp Safety PDF / 1 MB
FS EN 50156 Zertifikat SafeLOGIC, SafeIO PDF / 314 KB
FTZU 09 ATEX 0083X PDF / 771 KB
UK Declaration FS PLC X20 PDF / 112 KB
X20, X67 KC certificates PDF / 6 MB
Documentación Versión (fecha) Descargar
Data sheet X20(c)SOx530 - Legacy PDF / 1 MB
Data sheet X20(c)SOx530 - mapp Safety PDF / 1 MB
Installation- / EMC-Guide PDF / 20 MB
X20 Package leaflet ATEX/CSA PDF / 2 MB
X20 System User´s Manual PDF / 7 MB
E-CAD (plantillas Electro o EPLAN) Versión (fecha) Descargar
X20 EPLAN P8 from V2.4 EXE / 160 MB
Herramientas/Utilidades/Ejemplos Versión (fecha) Descargar
Sistema library ZIP / 336 KB
M-CAD (plantillas mecánicas) Versión (fecha) Descargar
3D file STEP X20Sxxx - Terminal block left side ZIP / 19 KB
DFX File I/O Slice ZIP / 4 KB
Dimensions PDF X20 I/O Slice PDF / 45 KB

Seleccione país e idioma

B&R Logo