Short description
I/O module 2-channel PWM output (H bridge)
2x 3 inputs for ABR incremental encoder
General information
B&R ID code 0x2273
Sensor power supply Max. 0.02 A per group
Status indicators
Output Per channel
Input Per group (3 inputs)
Other Supply voltage, bus function
Diagnostics
Outputs Yes, open circuit via software status
I/O power supply Yes, using LED status indicator and software
Connection type
X2X Link M12, B-coded
Inputs/Outputs 4x M12, A-coded
I/O power supply M8, 4-pin
Power consumption
Internal I/O 1 W
X2X Link power supply 0.75 W
Certifications
CE Yes
UKCA Yes
ATEX Zone 2, II 3G Ex nA IIA T5 Gc
IP67, Ta = 0 - Max. 60°C
TÜV 05 ATEX 7201X
UL cULus E115267
Industrial control equipment
HazLoc cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
KC Yes
I/O power supply
Nominal voltage 24 to 38.5 VDC ±25%
Power consumption
Sensor power supply Max. 1 W
Integrated protection
Reverse polarity protection No
Digital inputs
Quantity 6
Nominal voltage 24 VDC
Input characteristics per EN 61131-2 Type 1
Input voltage 24 VDC (-15%/+20%)
Input current at 24 VDC Approx. 4 mA
Input circuit Sink
Input filter
Hardware <5 µs
Software -
Input resistance Typ. 5.4 kΩ
Additional functions 2x ABR incremental encoder (+24 VDC),
2x AB incremental encoder,
2x event counter,
2x period duration / gate measurement
Switching threshold
Low <5 VDC
High >15 VDC
Insulation voltage between channel and bus 500 Veff
ABR incremental encoder
Quantity 2
Encoder inputs 24 VDC, asymmetrical
Counter size 16-bit
Input frequency Max. 50 kHz
Evaluation 4x
Encoder power supply Module-internal, max. 20 mA per encoder
Signal form Square wave pulse
Counter 1 Inputs 1 to 3
Counter 2 Inputs 4 to 6
Counter frequency Max. 200 kHz
Sensor power supply
Supply voltage 24 VDC
Short-circuit proof Yes
Supply voltage
Min. voltage at 20 mA / group 20 VDC
PWM output
Quantity 2
Type H bridge
Nominal voltage 24 to 38.5 VDC ±25%
PWM frequency 15 Hz to 50 kHz
Variant H bridge
Configurable dither Amplitude, frequency
Period duration resolution 16-bit, min. 20 μs
Phase shift PWM1 to PWM2 180°
DC bus capacitance 200 µF
Output current
Nominal current 3 A
Max. current/output 5 A for 2 s (after a recovery time of at least 10 s at maximum 3 A)
Max. current/module 8 A
PWM pulse width
PWM mode 15 bits plus sign ≥10 ns
Current mode 15 bits plus sign ≥10 ns
Electrical properties
Electrical isolation Channel isolated from bus
Channel not isolated from channel
Operating conditions
Mounting orientation
Any Yes
Installation elevation above sea level
0 to 2000 m No limitation
>2000 m Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529 IP67
Ambient conditions
Temperature
Operation -25 to 55°C
Derating -
Storage -40 to 85°C
Transport -40 to 85°C
Mechanical properties
Dimensions
Width 53 mm
Height 85 mm
Depth 42 mm
Weight 225 g
Torque for connections
M8 Max. 0.4 Nm
M12 Max. 0.6 Nm
Materiálové číslo:
X67MM2436
Popis:
  • 2x outputs (H bridge) with PWM control and 24 to 38.5 VDC ±25% supply
    • 3 A rated current (5 A max current)
    • 15 Hz to 50 kHz frequency, 16-bit
    • PWM resolution, 15-bit, + sign, minimum 10 ns
    • Configurable dither
  • 2x 3 inputs 24 V, can be configured as ABR
    • Sink connection
    • Integrated sensor supply with short circuit protection
    • 1-wire connections
    • 24 VDC and GND for encoder supply

This motor bridge module is used to control 2 DC motors with a nominal voltage of 24 to 38.5 VDC ±25% at a nominal current up to 3 A. The module can be reconfigured and used in current controller mode for controlling inductive loads. The module is also equipped with 6 digital inputs, which can be used as incremental counters. Each motor is controlled with a full-bridge (H-bridge). This enables the motors to be moved in both directions.

Automation Studio HW Upgrades Verze (datum) Ke stažení
V2.6 HW Upgrade (X67MM2436) EXE / 2 MB
V3.0 HW Upgrade (X67MM2436) EXE / 3 MB
V4.0 HW Upgrade (X67MM2436) EXE / 2 MB
Certifikáty Verze (datum) Ke stažení
244665 CSA HazLoc CoC X20, X67 PDF / 158 KB
E115267 UL CoC X67 PDF / 155 KB
EU Declaration ATEX X67 PDF / 191 KB
EU Declaration PLC X67 PDF / 674 KB
Safe cutoff of potential groups PDF / 211 KB
TÜV 05 ATEX 7201 X PDF / 5 MB
UK Declaration PLC X67 PDF / 469 KB
X20, X67 KC certificates PDF / 6 MB
Dokumentace Verze (datum) Ke stažení
Data sheet X67MM2436 PDF / 912 KB
Installation- / EMC-Guide PDF / 20 MB
X67 System User´s Manual PDF / 6 MB
E-CAD (Electro or EPLAN Templates) Verze (datum) Ke stažení
X67 EPLAN P8 from V2.4 EXE / 105 MB
M-CAD (Mechan. Templates) Verze (datum) Ke stažení
3D File DXF/STEP X67 ZIP / 4 MB

Vyberte prosím zemi a jazyk

B&R Logo