DWL@DWL10000804028

Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
1.4.3.0 * 15.11.2024 572 кБ EXE AS6_HW_6PPT30.101G-20W.exe
Описание V6.0 HW Upgrade (6PPT30.101G-20W)

Revision information 6PPT30.101G-20W

Version 1.4.3.0:

ID: AQAJ-7161
Adjustments between PPT30Image V1.7.0 and HWX upgrade V1.4.3.0:
- No certificate error warnings will be shown, default value is disabled.
- Wait for initial NTP sync, default value is disabled.
- Use remanent memory for local storage, default value is disabled.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.4.2.0:

ID: 762700
6PPT30: implement additonal data point TerminalModuleID in the OPCUA IOMapping.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 762705
Adjusted Sampling and Publishing Intervall for the OPCUA data points TerminalLoadCPU,TerminalMemoryTotal and TerminalMemoryAvailable to the OPCUA server limits.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

Version 1.4.1.0:

ID: 757225
Implemented Update via HTTP and minor adjustments between T30 image and HWX:
1. Implemented Update via HTTP, supported from T30 image V1.6.0.0.
2. Buzzer set to On, FTP User and Passwort set to empty entry, DNS Suffix setto empty entry.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 761850
6PPT30: implement additonal data points in the OPCUA IOMapping:
OPCUA data points TerminalTemperature, TerminalLoadCPU, TerminalMemoryTotaland TerminalMemoryAvailable implemented.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

Version 1.3.5.0:

ID: 744020
New help with error correction implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

Version 1.3.3.0:

ID: 718125
Bugfix: if several PPT30 were used in one project, loading a panel configuration from the CPU failed.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.3.2.0:

ID: 700190
wrong apperance within the SDM
Expansion within the HWX necessary to fix SDM depiction
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

Version 1.3.1.0:

ID: 633715
Bugfix: "OPCUAconnectionOK"
"OPCUAconnectionOK" is supported starting with AR 4.51.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.3.0.0:

ID: 613310
Function extension Home Button with OPC UA
VK1 and VK2 are now showing in the IO Mapping of the Panel
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.1.0.0:

ID: 458470
function extension
Implementing an additional button that covers the unused touch area. This feature requires upgrade version 1.1.0.0, and the Image Version 1.0.4. Furtere information is contained in the documentation.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.6:

ID: 423535
Support of >AS 4.2.2.x
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

Version 1.0.0.5:

ID: 411885
Support of 6PPT30.043F-20B
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Loading