General information
Certifications
CE Yes
UKCA Yes
UL cULus E115267
Industrial control equipment
HazLoc cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
Cable construction
Wire cross section 2x 0.5 mm2 (20 AWG)
2x 2.5 mm2 (13 AWG)
Conductor resistance At 0.5 mm2 max. 39 Ω/km
At 2.5 mm2 max. 7.98 Ω/km
Outer jacket
Material Thermoplastic PVC-based material
Color Window gray (similar to RAL 7040)
Connector
Type 4-pin screw clamp terminal block
Electrical properties
Operating voltage Max. 30 VDC
Peak operating voltage Typ. 30 VDC
Test voltage
Wire - Wire 1500 V
Current-carrying capacity 10 A at 20°C
Operating conditions
Pollution degree per EN 61131-2 Pollution degree 2
Ambient conditions
Temperature
Moving -5 to 70°C
Static -30 to 70°C
Mechanical properties
Dimensions
Length 3 m
Diameter 7 mm
Bend radius
Moving 10x wire diameter
Fixed installation 5x wire diameter
Weight Approx. 250 g
Materiaalnummer:
5CAUPS.0030-01
Omschrijving:

The UPS connection cable, which is 3 m long, establishes the connection between the UPS interface option and the battery unit.