DWL@DWL10000064156
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
|---|---|---|---|---|---|---|
| 1.4.1.7 | * | 25/06/2012 | 1 Mo | EXE | AS3.0_HW_X20SO2110.exe | |
| Description |
V3.0 HW Upgrade (X20SO2110) Revision information X20SO2110 Version 1.4.1.7: ID: 290275 Changed help to html format Changedhelp to html format Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.4.1.3: ID: 284625 Release für kompatibles Safety Release 1.5 ID 284600 Parameter for backwards compatibility in description file changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.4.1.1: ID: 180850 Release for Safety Release 1.5 Release for Safety Release 1.5 Channeldescription changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.4.0.1: ID#225425: Safety Release 1.4 - different levels for logger entires: "Info", "Warning" or "Error" (ARB3.05 required) - logger entries with level "Info" or "Warning" are sent by only 1 of the 2safety processors to reduce the number of messages - X2X diagnostics data points (AR 3.08 required) Channel description changed: Yes Configuration description changed:No Firmware changed: Yes Version 1.2.0.3: ID#213410: changes in HWC fixed typos of safety parameters enabled for AR B2.96 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.2.0.0: ID#186435: reduced async communication at boot time parameters are stored locally and will only be transmitted in case of changes Channel description changed: No Configuration description changed: No Firmware changed: No ID#189430: automatic restart An automatic restart canbe configured. This enables switching of the digital output without another edge of the release signal. Channel description changed: No Configuration description changed: No Firmware changed: No ID#193060: flashing of SE-LEDs new states of SE-LEDs: single flash: safety firmware is still in state PreOp (waiting for start command from SL) double flash: safety firmware is in operational, but cyclic data connectionto SL is not valid Channel description changed: No Configuration description changed: No Firmware changed: Yes ID#201725: operation in cold environment problemswhen operating in cold environment (0 .. 10°C) solved (loggerentries 99850 und 103946) Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.1.5.0: ID#191000: Problems with PhysicalStateChannel The availability of the PhysicalStateChannels is not configurable anymore. This avoids possible mapping problems Channeldescription changed: No Configuration description changed: No Firmware changed: No Version 1.1.4.0: ID#183545: solved sporadic firmware update problems solved sporadic firmware update problems Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.1.3.0: ID#180215: boot problems at certain X2X cycle times failsafe state during boot when running at certain X2X cycle times (logger entries 119460 and 115364) Channel description changed: No Configuration description changed: No Firmware changed: No ID#182430: enhacements HWC restart inhibit state information can be mapped Aprol support Channel description changed: No Configuration description changed: No Firmware changed: No Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Version 1.1.2.0: ID: 179300 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No |
|||||