Short description
Communication module | 1x X2X Link master |
General information
B&R ID code | 0x1F24 |
Status indicators | Module status, data transfer |
Diagnostics | |
Module status | Yes, using status LED |
Data transfer | Yes, using status LED |
Power consumption | 0.97 W |
Additional power dissipation caused by actuators (resistive) [W] | - |
Certifications | |
CE | Yes |
ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
UL |
cULus E115267 Industrial control equipment |
HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
EAC | Yes |
KC | Yes |
Interfaces
Interface IF1 | |
Fieldbus | X2X Link master |
Variant | 4-pin male multipoint connector |
Number of stations | Max. 253 |
Internal bus power supply | No |
Network topology | Line |
Distance between 2 stations | Max. 100 m |
Bus terminating resistor | Internal |
Electrical properties
Electrical isolation | PLC isolated from X2X Link (IF1) |
Operating conditions
Mounting orientation | |
Horizontal | Yes |
Vertical | Yes |
Installation elevation above sea level | |
0 to 2000 m | No limitations |
>2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
Degree of protection per EN 60529 | IP20 |
Ambient conditions
Temperature | |
Operation | |
Horizontal mounting orientation | -25 to 60°C |
Vertical mounting orientation | -25 to 50°C |
Derating | - |
Storage | -40 to 85°C |
Transport | -40 to 85°C |
Relative humidity | |
Operation | 5 to 95%, non-condensing |
Storage | 5 to 95%, non-condensing |
Transport | 5 to 95%, non-condensing |
Mechanical properties
Note | Order 1x TB704 terminal block separately |
Slot | In X20 CPU |

Material number:
X20IF1091Description:
- X2X Link connection
The interface module can be used to expand the X20 CPU for specific applications. It is equipped with an X2X Link master interface.
Mandatory Accessories
Automation Studio HW Upgrades | Version (Date) | Download |
---|---|---|
V2.6 HW Upgrade (X20IF1091) | EXE / 457 KB | |
V3.0 HW Upgrade (X20IF1091) | EXE / 457 KB | |
V4.0 HW Upgrade (X20IF1091) | EXE / 628 KB |
Certificates | Version (Date) | Download |
---|---|---|
244665 CSA HazLoc Certificate of Compliance X20, X67 | PDF / 56 KB | |
E115267 UL CoC X20 | PDF / 847 KB | |
FTZU 09 ATEX 0083X | PDF / 697 KB | |
X20, X67 KC certificates | PDF / 6 MB |
Documentation | Version (Date) | Download |
---|---|---|
Datasheet X20IF1091 | PDF / 142 KB | |
X20 System User´s Manual | PDF / 56 MB |
E-CAD (Electro or EPLAN Templates) | Version (Date) | Download |
---|---|---|
X20 EPLAN P8 from V2.4 | EXE / 161 MB |
M-CAD (Mechan. Templates) | Version (Date) | Download |
---|---|---|
3D File DXF/STEP X20 Interface module X20IF1091/10A1-1 | ZIP / 26 KB | |
Dimensions PDF X20 Interface Module X20IF1091/10A1-1 | PDF / 4 KB |