Por favor elija país e idioma:

Short description
Bus controller Modbus TCP/UDP esclavo
General information
B&R ID code 0x227C
Status indicators Estado del módulo, función del bus
Diagnostics
Module status Sí, mediante LED de estado y estado del software
Bus function Sí, mediante LED de estado y estado del software
Power consumption
Bus 2 W
Additional power dissipation caused by actuators (resistive) [W] -
Electrical isolation
Fieldbus - X2X Link
Fieldbus - I/O
Certifications
CE Yes
ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
UL cULus E115267
Industrial control equipment
HazLoc cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
DNV GL Environmental category D, EMC1
LR ENV1
KC Yes
Interfaces
Fieldbus Modbus TCP/UDP esclavo
Variant 2x RJ45 protegidos (interruptor)
Cable length Un max de 100m entre las 2 estaciones (longitud del segmento)
Transfer rate 10/100 Mbit/s
Transfer
Physical layer 10 BASE-T/100 BASE-TX
Half-duplex
Full-duplex
Autonegotiation
Auto-MDI/MDIX
Min. cycle time
Fieldbus 1 ms
X2X Link 500 μs
Synchronization between bus systems possible No
Operating conditions
Mounting orientation
Horizontal
Vertical
Installation elevation above sea level
0 to 2000 m Sin limitaciones
>2000 m Reducción de la temperatura ambiente en 0.5°C por 100 m
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation De -25 a 60 °C
Vertical mounting orientation De -25 a 50 °C
Derating -
Storage De -40 a 85 °C
Transport De -40 a 85 °C
Relative humidity
Operation De 5 a 95%, sin condensación
Storage De 5 a 95%, sin condensación
Transport De 5 a 95%, sin condensación
Mechanical properties
Note 1x terminal X20TB12 disponible por separado
1 x módulo de fuente de alimentación X20PS9400 o X20PS9402 disponible por separado
1x placa bus X20BB80 disponible por separado
Pitch 37.5 +0.2 mm
Material number:
X20BC0087
Description:
  • Fieldbus: Modbus/TCP, Modbus/UDP
  • I/O configuration via the fieldbus
  • DHCP-capable
  • Bootp-capable
  • Integrated double switch for efficient cabling
  • Configurable I/O cycle (0.5 to 4 ms)
  • Response time: <1 - 8 ms (depending on the load on the integrated switch)
  • Validity check for command sequences before execution

Established in 1979, the Modbus protocol has approved the use of Ethernet with both Modbus TCP and Modbus/UDP. Today, Modbus TCP is an open Internet draft standard introduced by Schneider Automation to the Internet Engineering Task Force (IETF), the organization responsible for Internet standardization. The Modbus services and object model have been preserved since the original version and left unchanged for use with the TCP/IP transmission medium.

Modbus/UDP differs from Modbus TCP in that it uses connectionless communication via UDP/IP. The advantages of faster and easier communication with UDP/IP also brings with it the disadvantage of requiring error detection and correction in the application layer.

This bus controller makes it possible to connect X2X Link I/O nodes to Modbus via Ethernet. The bus controller can be operated on B&R controllers through the use of Automation Studio or on third-party systems with Modbus TCP or -UDP master functionality.

Only the standard function model (see the respective module description) is supported when the bus controller is used together with multi-function modules it has automatically configured itself.

All other function models are supported when configured accordingly in Automation Studio V4.3 or later.

Automation Studio kann kostenlos von der B&R Webseite www.br-automation.com heruntergeladen werden. Die Evaluierungslizenz darf unentgeltlich zur Erstellung vollständiger Konfigurationen der Feldbus Bus Controller benützt werden.

Mandatory Accessories
System modules for bus controllers
X20BB80 X20 bus base, for X20 base module (BC, HB, etc.) and X20 power supply module, X20 end cover plates (left and right) X20AC0SL1/X20AC0SR1 included
X20PS9400 X20 power supply module, for bus controller and internal I/O power supply X2X Link power supply
X20PS9402 X20 power supply module, for bus controller and internal I/O power supply, X2X Link power supply, supply not electrically isolated
Terminal blocks
X20TB12 X20 Conector estándar 12 pines
Automation Studio HW Upgrades Version (Date) Download
V3.0 HW Upgrade (X20BC0087) EXE / 399 KB
V4.3 HW Upgrade (X20BC0087) EXE / 729 KB
Certificates Version (Date) Download
244665 CSA HazLoc Certificate of Compliance X20, X67 PDF / 56 KB
ABS Certificate of Product Design Assessment - X20 IO Series PDF / 2 MB
DNV GL Type Approval Certificate - X20 / Power Panel T30 PDF / 164 KB
Declaration of Conformence X20BC0087 PDF / 38 KB
E115267 UL CoC X20 PDF / 847 KB
FTZU 09 ATEX 0083X PDF / 697 KB
KR Type Approval Certificate MIL39390-AC003 (X20 System) PDF / 758 KB
Lloyds Register PDF / 506 KB
X20, X67 KC certificates PDF / 6 MB
Documentation Version (Date) Download
Data sheet X20(c)BC0087 PDF / 185 KB
Modbus/TCP Bus Controller User's manual PDF / 4 MB
X20 System User´s Manual PDF / 56 MB
E-CAD (Electro or EPLAN Templates) Version (Date) Download
X20 EPLAN P8 from V2.4 EXE / 161 MB
Fieldbus equipment description files Version (Date) Download
Modbus Mapping Tool ZIP / 160 KB
ModbusTCP Toolbox ZIP / 4 MB
M-CAD (Mechan. Templates) Version (Date) Download
3D File STEP/DXF X20BC and X20IF Module ZIP / 1 MB