Quantity |
3 |
Continuous power per motor connection |
4 / 4 / 4 kW |
Continuous current per motor connection |
8.8 / 8.8 / 8.8 AEff |
Reduction of continuous current depending on switching frequency |
|
Switching frequency 5 kHz |
0.373 A/K (from 45.2°C) |
Switching frequency 10 kHz |
0.154 A/K (from 18.5°C) |
Switching frequency 20 kHz |
0.075 A/K (from -50.9°C) |
Reduction of continuous current depending on installation elevation |
|
Starting at 500 m above sea level |
0.88 AEff per 1000 m |
Peak current per motor connection |
24 / 24 / 24 AEff |
Peak power output |
10 kW |
Nominal switching frequency |
5 kHz |
Possible switching frequencies |
5 / 10 / 20 kHz |
Electrical stress of connected motor per IEC TS 60034-25 |
Limit value curve A |
Protective measures |
|
Overload protection |
Yes |
Short circuit and ground fault protection |
Yes |
Max. output frequency |
598 Hz |
Variant |
|
U, V, W, PE |
Male connector |
Shield connection |
Yes |
Terminal connection cross section |
|
Flexible and fine-stranded wires |
|
With wire end sleeves |
1.5 to 6 mm² |
Approbation data |
|
UL/C-UL-US |
24 to 8 AWG |
CSA |
24 to 8 AWG |
Max. motor line length depending on switching frequency |
|
Switching frequency 5 kHz |
75 m |
Switching frequency 10 kHz |
37.5 m |
Switching frequency 20 kHz |
18.75 m |