Short description
I/O module 16 digital outputs 24 VDC for 1-wire connections
General information
B&R ID code 0xC0EA
Status indicators I/O function per channel, operating state, module status
Diagnostics
Module run/error Yes, using status LED and software
Outputs Yes, using status LED and software (output error status)
Power consumption
Bus 0.28 W
Internal I/O 0.95 W
Additional power dissipation caused by actuators (resistive) [W] +0.56 W
Certifications
CE Yes
KC Yes
EAC Yes
UL cULus E115267
Industrial control equipment
HazLoc cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
DNV GL Temperature: <strong>B</strong> (0 - 55°C)
Humidity: <strong>B</strong> (up to 100%)
Vibration: <strong>B</strong> (4 g)
EMC: <strong>B</strong> (bridge and open deck)
LR ENV1
KR Yes
Digital outputs
Variant FET positive switching
Nominal voltage 24 VDC
Switching voltage 24 VDC -15% / +20%
Nominal output current 0.5 A
Total nominal current 8 A
Connection type 1-wire connections
Output circuit Source
Output protection Thermal cutoff on overcurrent or short circuit (see value "Peak short circuit current")
Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")
Diagnostic status Output monitoring with 10 ms delay
Leakage current when switched off 5 µA
RDS(on) 140 mΩ
Peak short-circuit current <3 A
Switch-on in the event of overload shutdown or short-circuit shutdown Approx. 10 ms (depends on the module temperature)
Switching delay
0 → 1 <300 µs
1 → 0 <300 µs
Switching frequency
Resistive load Max. 500 Hz
Inductive load See section "Switching inductive loads"
Braking voltage when switching off inductive loads Typ. 45 VDC
Isolation voltage between channel and bus 500 V<sub>eff</sub>
Electrical properties
Electrical isolation Channel isolated from bus
Channel not isolated from channel
Operating conditions
Mounting orientation
Horizontal Yes
Vertical Yes
Installation elevation above sea level
0 to 2000 m No limitation
>2000 m Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation -25 to 60°C
Vertical mounting orientation -25 to 50°C
Derating See section "Derating"
Storage -40 to 85°C
Transport -40 to 85°C
Relative humidity
Operation 5 to 95%, non-condensing
Storage 5 to 95%, non-condensing
Transport 5 to 95%, non-condensing
Mechanical properties
Note Order 1x terminal block X20TB1F separately
Order 1x bus module X20BM11 separately
Spacing 12.5<sup>+0.2</sup> mm
Material number:
X20DOF322
Description:
  • 16 digital outputs
  • Source connection
  • 1-wire connections
  • Integrated output protection

The module is equipped with 16 outputs for 1-wire connections. The module is designed for source output wiring.

Mandatory Accessories
Bus modules
X20BM11 X20 bus module, 24 VDC keyed, internal I/O supply continuous
X20BM15 X20 bus module, with node number switch, 24 VDC keyed, internal I/O supply continuous
Terminal blocks
X20TB1F X20 terminal block, 16-pin, 24 VDC keyed
Automation Studio HW Upgrades Version (Date) Download
V2.7 HW Upgrade (X20DOF322) EXE / 1 MB
V3.0 HW Upgrade (X20DOF322) EXE / 2 MB
V4.0 HW Upgrade (X20DOF322) EXE / 776 KB
Certificates Version (Date) Download
DNV GL Type Approval Certificate - X20 / Power Panel T30 PDF / 171 KB
E115267 UL CoC X20 PDF / 825 KB
FTZU 09 ATEX 0083X PDF / 697 KB
KR Type Approval Certificate MIL39390-AC003 (X20 System) PDF / 758 KB
Lloyds Register PDF / 579 KB
Safe cutoff of potential groups PDF / 147 KB
Documentation Version (Date) Download
Data sheet X20(c)DOF322 PDF / 234 KB
X20 System User´s Manual PDF / 50 MB
E-CAD (Electro or EPLAN Templates) Version (Date) Download
X20 EPLAN P8 from V2.4 EXE / 161 MB
M-CAD (Mechan. Templates) Version (Date) Download
3D File DXF/STEP X20DxD3xx ZIP / 1 MB