Power Panel 300/400 MTCX Firmware Upgrade
---------------------------------------------------------------- GENERAL INFORMATION ----------------------------------------------------------------
With this disk you can update the MTCX firmware for FPGA and PX32 (PP3F/PP3P) on a B&R Power Panel 300/400.
---------------------------------------------------------------- UPDATE PROCEDURE ----------------------------------------------------------------
1. Copy all files to a bootable disk.
2. Insert the disk in a (USB) floppy drive connected to the Power Panel and re-boot the device.
3. A boot menu with following options is shown after booting:
1. Update MTCX Firmware (PX32/FPGA)
The MTCX Firmware FPGA and PX32 will be upgraded automatically (Default after 5 sec).
************************************* Do not abort a MTCX Firmware upgrade! *************************************
Otherwise the Power Panel cannot be rebooted afterwards and must be sent to B&R for repair. Retry the aborted update process WITHOUT rebooting the Power Panel, for example by directly calling batch file UPDMTCX.BAT.
2. Exit
Ausstieg in die Shell (MS-DOS).
4. Select the desired action.
5. Remove disk and reboot device (after successful update only!).
---------------------------------------------------------------- Version 01.09 / 2008-03-19 ----------------------------------------------------------------
Contents: 0019#0.fp 01.03 NEW 0019#0.fw 01.16 MTCXSVC.EXE 03.02 PPHOTFIX.EXE 01.00 LIESMICH.TXT 01.09 NEW README.TXT 01.09 NEW CONFIG.SYS AUTOEXEC.BAT UPDMTCX.BAT
Fixes: - FPGA (0019#0.fp): Bugfix in the power-on sequence, sporadic display switch-on problems with FPGA V1.02 are fixed.
Changes: - FPGA (0019#0.fp): Optimized backlight regulation.
|
|